Filter by category
Filter by Date
CHG0100544 - MSATS - CATS Production Site Transfer Brisbane to Norwest
Notification issued to: Market Notice
Notification Type: Initial
Change Type: Normal
Service/ Component: MSATS - Consumer Administration and Transfer Solution(CATS)
Change Title: MSATS - CATS Production Site Transfer Brisbane to Norwest
Change Start Date & Time: 02/03/2025 09:00:00
Change End Date & Time: 02/03/2025 15:00:00
Outage Start Date & Time: 02/03/2025 10:00:00
Outage End Date & Time: 02/03/2025 14:00:00
Environment: Production
Participant Impact and Requirements
The outage will affect logins to Web Portals, MSATS, WEMDEUI, OPDMS, NOS, TMM, Gas Supply Hub, Capacity Auction, and Gas Bulletin Board. API calls to these services will be unavailable during the URM outage.
Outage Windows:
MSATS: 10:00 - 14:00 AEST
URM: 11:15 - 11:45 AEST
Impacted Services:
Web Portals (Markets, Internal & Public) and the following systems:
WEMDEUI, GSH, GBB, MSATS, DERR, PMS, RERT, SIMMS, DWGM, EMMS, Market Notice, DI
Key Impacts:
MSATS, Meter Data Processing, RM reports, B2B, B2M screens, NMI Discovery, CDR, and CDP will be unavailable.
Logged-in users before the outage will not be affected, but logging out means waiting until the outage ends to log back in.
Password resets and new account creations during the URM outage must be redone.
MSATS and NOS Server FTP sessions will be disabled, but Wholesale MMS FTP will remain available.
Plain English constraints and the redirection menu will be unavailable during the outage.
Capacity auction bidding via the Markets Portal and direct API calls will be unavailable.
Gas Supply Hub will remain open for trading, but reports will be inaccessible via Publishing Direct.
Recommendation:
Users should log in before the outage and remain logged in to avoid disruptions.
Support Information:
Report any impacts to the AEMO Support Hub or call 1300 236 600.
Please refer to https://aemo.service-now.com/participantportal?id=pp_services_status for any planned/unplanned maintenance activities .
CHG0101364 - A production site transfer of the Electricity and Gas B2B Hub will be carried out to facilitate maintenance activities.
Notification issued to: Market Notice
Notification Type: Initial
Change Type: Normal
Service/ Component: Gas Hub
Change Title: A production site transfer of the Electricity and Gas B2B Hub will be carried out to facilitate maintenance activities.
Change Start Date & Time: 02/03/2025 09:00:00
Change End Date & Time: 02/03/2025 17:00:00
Outage Start Date & Time: 02/03/2025 10:00:00
Outage End Date & Time: 02/03/2025 14:00:00
Environment: Production
Participant Impact and Requirements: The following impacts are expected during this maintenance:
- All access to the Electricity B2B Hub will be unavailable.
- All access to the Gas B2B Hub and all ebXML gateways (AEMOMIBB, AGNLGWY, LVI & VENCORP) will be unavailable. CATS and MDMT transactions for VIC/QLD will be delayed during the maintenance window.
- Users are not required to take any action due to this change, however will need to enact manual workarounds for the outage period.
Support Information:
Report any impacts to the AEMO Information and Support Hub or call 1300 236 600.
Please refer to https://aemo.service-now.com/participantportal?id=pp_services_status for any planned/unplanned maintenance activities .
Yass to Wagga control scheme change - removal system normal constraint equations in NSW managing 990, 991 and 970 132kV lines
Transgrid has advised AEMO of an update to the Yass overload trip scheme. The scheme is normally armed managing line flow on 990, 991, 970 132kV lines and it is now operating both directions of flow from Wagga to Yass.
Based on this advice, the following constraint equations will be removed from the NSW system normal constraint sets N-NIL and N-NIL_991, effective immediately.
N>>NIL_970_051
N>>NIL_990_051
N>>NIL_991_051
Ben Blake
AEMO Operations
NEM Local Temperature Alerts for SA, VIC from 24 Feb 2025 to 28 Feb 2025
AEMO's weather service provider has issued forecast temperatures equal to or greater than the NEM Local Temperature Alert Levels for listed weather stations below.
SA
Port Augusta Ap (39+ Deg C): 27th Feb
VIC
Mildura Ap (39+ Deg C): 26th Feb, 27th Feb
The NEM Local Temperature Alert Levels are:
Launceston Ti Tree Bend: 33 Deg C, Dalby Airport: 37 Deg C, for all other selected weather stations: 39 Deg C.
AEMO requests Market Participants to:
1. review the weather forecast in the local area where their generating units / MNSP converter stations are located and,
2. if required, update the available capacity in their dispatch offers or availability submissions consistent with the forecast temperatures.
Further information is available at:
https://aemo.com.au/energy-systems/electricity/national-electricity-market-nem/nem-forecasting-and-planning/forecasting-and-reliability/projected-assessment-of-system-adequacy/nem-local-temperature-alerts
AEMO Operations Planning
Completed - CHG0100546 - Production eMDM February Maintenance Release
Notification issued to: Market Notice
Notification Type: Completed
Change Type: Normal
Service/Component: MDM - Meter Data Management
Change Title: Production eMDM February Maintenance Release
Support Information: Report any impacts to the AEMO Information and Support Hub or on External 1300 236 600.
Inter-regional transfer limit variation - BassLink Harmonic Filter - TAS region - 23/02/2025
Inter-regional transfer limit variation - BassLink Harmonic Filter - TAS region - 23/02/2025
At 0305 hrs 23/02/2025 there was an unplanned outage of BassLink Harmonic Filter.
The following constraint set(s) invoked at 0305 hrs 23/02/2025
T-BLGC_HF_43MVAR
This constraint set(s) contains equations with the following interconnectors on the LHS.
T-V-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Collector Windfarm - Yass (3L) 330 kV line - NSW region - 22/02/2025
Inter-regional transfer limit variation - Collector Windfarm - Yass (3L) 330 kV line - NSW region - 22/02/2025
A planned outage of Collector Windfarm - Yass (3L) 330 kV line in the NSW region was scheduled from 0600 hrs 17/02/2025 to 1600 hrs 24/02/2025.
The outage has been completed and Collector Windfarm - Yass (3L) 330 kV line returned to service at 0746 hrs 22/02/2025
Constraint set(s) revoked: N-CTYS_3L_WG_CLOSE
Manager NEM Real Time Operations
NEM Local Temperature Alerts for SA, VIC from 21 Feb 2025 to 25 Feb 2025
AEMO's weather service provider has issued forecast temperatures equal to or greater than the NEM Local Temperature Alert Levels for listed weather stations below.
SA
Mt Gambier Ap (39+ Deg C): 22nd Feb
Port Augusta Ap (39+ Deg C): 22nd Feb, 25th Feb
VIC
Mildura Ap (39+ Deg C): 22nd Feb
Mortlake (39+ Deg C): 22nd Feb
The NEM Local Temperature Alert Levels are:
Launceston Ti Tree Bend: 33 Deg C, Dalby Airport: 37 Deg C, for all other selected weather stations: 39 Deg C.
AEMO requests Market Participants to:
1. review the weather forecast in the local area where their generating units / MNSP converter stations are located and,
2. if required, update the available capacity in their dispatch offers or availability submissions consistent with the forecast temperatures.
Further information is available at:
https://aemo.com.au/energy-systems/electricity/national-electricity-market-nem/nem-forecasting-and-planning/forecasting-and-reliability/projected-assessment-of-system-adequacy/nem-local-temperature-alerts
AEMO Operations Planning
NEM Local Temperature Alerts for SA, VIC from 20 Feb 2025 to 24 Feb 2025
AEMO's weather service provider has issued forecast temperatures equal to or greater than the NEM Local Temperature Alert Levels for listed weather stations below.
SA
Adelaide West Terrace (39+ Deg C): 22nd Feb
Clare High School (39+ Deg C): 22nd Feb
Mt Gambier Ap (39+ Deg C): 22nd Feb
Port Augusta Ap (39+ Deg C): 22nd Feb
VIC
Mildura Ap (39+ Deg C): 22nd Feb
Mortlake (39+ Deg C): 22nd Feb
The NEM Local Temperature Alert Levels are:
Launceston Ti Tree Bend: 33 Deg C, Dalby Airport: 37 Deg C, for all other selected weather stations: 39 Deg C.
AEMO requests Market Participants to:
1. review the weather forecast in the local area where their generating units / MNSP converter stations are located and,
2. if required, update the available capacity in their dispatch offers or availability submissions consistent with the forecast temperatures.
Further information is available at:
https://aemo.com.au/energy-systems/electricity/national-electricity-market-nem/nem-forecasting-and-planning/forecasting-and-reliability/projected-assessment-of-system-adequacy/nem-local-temperature-alerts