[EventId:202502041520_confirmed] Prices for interval 04-Feb-2025 15:20 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1540 hrs on 4 February 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Feb-2025 15:20.
In accordance with Market Notice 124101 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202502041540_confirmed] Prices for interval 04-Feb-2025 15:40 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1540 hrs on 4 February 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Feb-2025 15:40.
In accordance with Market Notice 124107 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202502041535_confirmed] Prices for interval 04-Feb-2025 15:35 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1540 hrs on 4 February 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Feb-2025 15:35.
In accordance with Market Notice 124105 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202502041530_confirmed] Prices for interval 04-Feb-2025 15:30 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1540 hrs on 4 February 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Feb-2025 15:30.
In accordance with Market Notice 124104 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202502041525_confirmed] Prices for interval 04-Feb-2025 15:25 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1540 hrs on 4 February 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Feb-2025 15:25.
In accordance with Market Notice 124103 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202502041515_confirmed] Prices for interval 04-Feb-2025 15:15 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1540 hrs on 4 February 2025
PRICES ARE NOW CONFIRMED for trading interval 04-Feb-2025 15:15.
In accordance with Market Notice 124099 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
Reclassification of a Non-Credible Contingency Event: Guybal Munjan - Chalumbin 857 275kV line line and Guybal Munjan - Chalumbin 858 275kV line line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Guybal Munjan - Chalumbin 857 275kV line and Guybal Munjan - Chalumbin 858 275kV line
Duration: 04/02/2025 15:38 until further notice
Constraint set(s) invoked:
Q-RSCH_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Bayswater - Mt Piper No.5A3 500kV line and Wollar - Mt Piper No.5A5 500kV line in NSW1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: NSW1
Lines: Bayswater - Mt Piper No.5A3 500kV and Wollar - Mt Piper No.5A5 500kV
Duration: 04/02/2025 15:38 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Kamerunga - Barron Gorge 7184 132kV line and Kamerunga - Barron Gorge 7143 132kV line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Kamerunga - Barron Gorge 7184 132kV and Kamerunga - Barron Gorge 7143 132kV
Duration: 04/02/2025 15:18 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations