Filter by category
Filter by Date
[EventId:202502051800_review] Prices for interval 05-Feb-2025 18:00 are subject to review
Issued by Australian Energy Market Operator Ltd at 1755 hrs on 5 February 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 05-Feb-2025 18:00.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202502051755_review] Prices for interval 05-Feb-2025 17:55 are subject to review
Issued by Australian Energy Market Operator Ltd at 1750 hrs on 5 February 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 05-Feb-2025 17:55.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202502051750_review] Prices for interval 05-Feb-2025 17:50 are subject to review
Issued by Australian Energy Market Operator Ltd at 1745 hrs on 5 February 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 05-Feb-2025 17:50.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202502051745_review] Prices for interval 05-Feb-2025 17:45 are subject to review
Issued by Australian Energy Market Operator Ltd at 1740 hrs on 5 February 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 05-Feb-2025 17:45.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202502051740_review] Prices for interval 05-Feb-2025 17:40 are subject to review
Issued by Australian Energy Market Operator Ltd at 1735 hrs on 5 February 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 05-Feb-2025 17:40.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202502051735_NRM_NSW1_VIC1_started] NEGRES CONSTRAINT NRM_NSW1_VIC1 started operating from 05 February 2025 17:35
Issued by Australian Energy Market Operator Ltd at 1735 hrs on 5 February 2025
ACTUAL NEGATIVE SETTLEMENT RESIDUES - NSW to VIC - 5 February 2025.
Electricity Market outcomes have resulted in the accumulation of negative settlement residues that have exceeded the allowable negative residue threshold for the NSW to VIC directional interconnector.
The negative residue constraint set NRM_NSW1_VIC1 commenced operating from 1735 hrs on 5 February 2025.
This constraint set contains an equation with the following interconnectors on the LHS:
VIC1-NSW1
The RHS of the constraint equation may be adjusted to manage residues.
This is an AEMO autogenerated Market Notice.
[EventId:202502051735_review] Prices for interval 05-Feb-2025 17:35 are subject to review
Issued by Australian Energy Market Operator Ltd at 1730 hrs on 5 February 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 05-Feb-2025 17:35.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202502051545_NRM_NSW1_VIC1_stopped] NEGRES CONSTRAINT NRM_NSW1_VIC1 ceased operating from 05 February 2025 15:45
Issued by Australian Energy Market Operator Ltd at 1545 hrs on 5 February 2025
CANCELLATION - ACTUAL NEGATIVE SETTLEMENT RESIDUES - NSW to VIC - 5 February 2025.
Refer to market notice: 124174
AEMO has ceased taking action to minimize the further accumulation of negative settlement residues on the NSW to VIC directional interconnector.
The negative residue constraint NRM_NSW1_VIC1 ceased operating at 1545 hrs on 5 February 2025.
This is an AEMO autogenerated Market Notice.
Update - Non-credible contingency event - TAS region - 03/02/2025
Update - Non-credible contingency event - TAS region - 03/02/2025
Refer AEMO Electricity Market Notice 124044
The cause of this non-credible contingency event has been identified and AEMO is satisfied that another occurrence of this event is unlikely under the current circumstances.
AEMO will cancel the reclassification of this event as a credible contingency event.
Manager NEM Real Time Operations