Market Notices

115555PRICES SUBJECT TO REVIEW09/03/2024 04:30:17 PM

[EventId:202403091635_review] Prices for interval 09-Mar-2024 16:35 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1630 hrs on 9 March 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 09-Mar-2024 16:35.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
115554PRICES SUBJECT TO REVIEW09/03/2024 04:25:18 PM

[EventId:202403091630_review] Prices for interval 09-Mar-2024 16:30 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1625 hrs on 9 March 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 09-Mar-2024 16:30.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
115553PRICES SUBJECT TO REVIEW09/03/2024 04:20:17 PM

[EventId:202403091625_review] Prices for interval 09-Mar-2024 16:25 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1620 hrs on 9 March 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 09-Mar-2024 16:25.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
115552RESERVE NOTICE09/03/2024 02:40:29 PM

STPASA - Forecast Lack Of Reserve Level 1 (LOR1) in the NSW Region on 14/03/2024

AEMO ELECTRICITY MARKET NOTICE

AEMO declares a Forecast LOR1 condition under clause 4.8.4(b) of the National Electricity Rules for the NSW region for the following period:

[1.] From 1800 hrs 14/03/2024 to 1830 hrs 14/03/2024.
The forecast capacity reserve requirement is 1780 MW.
The minimum capacity reserve available is 1493 MW.

Manager NEM Real Time Operations
115550RECLASSIFY CONTINGENCY09/03/2024 02:04:22 PM

Reclassification of a Non-Credible Contingency Event: Tully - Cardwell No.7389 132 kV line and Ross - Woree No. 8905 275 kV line

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly, AEMO has reclassified it as a credible contingency event.

Region: QLD1

Lines: Tully - Cardwell No.7389 132 kV line and Ross - Woree No. 8905 275 kV line

Duration: 09/03/2024 13:55 until further notice

Constraint set(s) invoked: NONE


Manager NEM Real Time Operations
115546GENERAL NOTICE08/03/2024 10:31:51 AM

NEM Local Temperature Alerts for SA, TAS, VIC from 08 Mar 2024 to 12 Mar 2024

AEMO ELECTRICITY MARKET NOTICE

AEMO's weather service provider has issued forecast temperatures equal to or greater than the NEM Local Temperature Alert Levels for listed weather stations below.

SA
Adelaide West Terrace (39+ Deg C): 9th Mar, 10th Mar
Mt Gambier Ap (39+ Deg C): 9th Mar, 11th Mar
Port Augusta Ap (39+ Deg C): 8th Mar, 9th Mar, 10th Mar, 11th Mar, 12th Mar

TAS
Launceston Ti Tree Bend (33+ Deg C): 10th Mar

VIC
Latrobe Valley Ap (39+ Deg C): 9th Mar, 10th Mar, 11th Mar
Mildura Ap (39+ Deg C): 9th Mar, 10th Mar, 11th Mar, 12th Mar
Mortlake (39+ Deg C): 9th Mar, 11th Mar

The NEM Local Temperature Alert Levels are:

Launceston Ti Tree Bend: 33 Deg C, Dalby Airport: 37 Deg C, for all other selected weather stations: 39 Deg C.

AEMO requests Market Participants to:

1. review the weather forecast in the local area where their generating units / MNSP converter stations are located and,

2. if required, update the available capacity in their dispatch offers or availability submissions consistent with the forecast temperatures.

Further information is available at:

https://aemo.com.au/energy-systems/electricity/national-electricity-market-nem/nem-forecasting-and-planning/forecasting-and-reliability/projected-assessment-of-system-adequacy/nem-local-temperature-alerts

AEMO Operations Planning
115545RECLASSIFY CONTINGENCY07/03/2024 04:59:50 PM

Cancellation of a Non-Credible Contingency Event: Collinsville - Stoney Creek 7306 132KV LINE line and Collinsville - Newlands 7121 132KV LINE line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: QLD1

Lines: Collinsville - Stoney Creek 7306 132KV LINE and Collinsville - Newlands 7121 132KV LINE

Cancellation time: 07/03/2024 16:59

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 115543

Auto-generated on behalf of Manager NEM Real Time Operations
115544RECLASSIFY CONTINGENCY07/03/2024 04:34:50 PM

Cancellation of a Non-Credible Contingency Event: Bayswater - Mt Piper No.5A3 500kV line and Wollar - Mt Piper No.5A5 500kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: NSW1

Lines: Bayswater - Mt Piper No.5A3 500kV and Wollar - Mt Piper No.5A5 500kV

Cancellation time: 07/03/2024 16:34

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 115534

Auto-generated on behalf of Manager NEM Real Time Operations
115543RECLASSIFY CONTINGENCY07/03/2024 03:57:40 PM

Reclassification of a Non-Credible Contingency Event: Collinsville - Stoney Creek 7306 132KV LINE line and Collinsville - Newlands 7121 132KV LINE line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: QLD1

Lines: Collinsville - Stoney Creek 7306 132KV LINE and Collinsville - Newlands 7121 132KV LINE

Duration: 07/03/2024 15:57 until further notice

Constraint set(s) invoked:
NONE

Auto-generated on behalf of Manager NEM Real Time Operations