Market Notices

121575PRICES UNCHANGED07/12/2024 11:15:21 AM

[EventId:202412071050_confirmed] Prices for interval 07-Dec-2024 10:50 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1115 hrs on 7 December 2024

PRICES ARE NOW CONFIRMED for trading interval 07-Dec-2024 10:50.

In accordance with Market Notice 121569 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
121574PRICES SUBJECT TO REVIEW07/12/2024 11:10:18 AM

[EventId:202412071115_review] Prices for interval 07-Dec-2024 11:15 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1110 hrs on 7 December 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 07-Dec-2024 11:15.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
121573PRICES SUBJECT TO REVIEW07/12/2024 11:05:24 AM

[EventId:202412071110_review] Prices for interval 07-Dec-2024 11:10 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1105 hrs on 7 December 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 07-Dec-2024 11:10.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
121572PRICES SUBJECT TO REVIEW07/12/2024 11:00:21 AM

[EventId:202412071105_review] Prices for interval 07-Dec-2024 11:05 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1100 hrs on 7 December 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 07-Dec-2024 11:05.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
121571PRICES SUBJECT TO REVIEW07/12/2024 10:55:17 AM

[EventId:202412071100_review] Prices for interval 07-Dec-2024 11:00 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1055 hrs on 7 December 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 07-Dec-2024 11:00.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
121570PRICES SUBJECT TO REVIEW07/12/2024 10:50:18 AM

[EventId:202412071055_review] Prices for interval 07-Dec-2024 10:55 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1050 hrs on 7 December 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 07-Dec-2024 10:55.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
121569PRICES SUBJECT TO REVIEW07/12/2024 10:45:24 AM

[EventId:202412071050_review] Prices for interval 07-Dec-2024 10:50 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1045 hrs on 7 December 2024

PRICES ARE SUBJECT TO REVIEW for trading interval 07-Dec-2024 10:50.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
     
121568RECLASSIFY CONTINGENCY07/12/2024 09:38:58 AM

Reclassification of a Non-Credible Contingency Event: Bannaby - Mt Piper 5A6 500kV line and Bannaby - Mt Piper 5A7 500kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: NSW1

Lines: Bannaby - Mt Piper 5A6 500kV and Bannaby - Mt Piper 5A7 500kV

Duration: 07/12/2024 09:38 until further notice

Constraint set(s) invoked:
N-5A6+5A7_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1
VIC1-NSW1


Auto-generated on behalf of Manager NEM Real Time Operations
     
121567RECLASSIFY CONTINGENCY07/12/2024 09:04:21 AM

Cancellation of a Non-Credible Contingency Event: Bannaby - Mt Piper 5A6 500kV line and Bannaby - Mt Piper 5A7 500kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: NSW1

Lines: Bannaby - Mt Piper 5A6 500kV and Bannaby - Mt Piper 5A7 500kV

Cancellation time: 07/12/2024 09:04

Constraint set(s) revoked:
N-5A6+5A7_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1
VIC1-NSW1


Refer AEMO Electricity Market Notice 121565

Auto-generated on behalf of Manager NEM Real Time Operations
     