Market Notices

121198PRICES UNCHANGED28/11/2024 07:16:33 PM

[EventId:202411281900_confirmed] Prices for interval 28-Nov-2024 19:00 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1915 hrs on 28 November 2024

PRICES ARE NOW CONFIRMED for trading interval 28-Nov-2024 19:00.

In accordance with Market Notice 121193 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
121197PRICES UNCHANGED28/11/2024 07:15:22 PM

[EventId:202411281855_confirmed] Prices for interval 28-Nov-2024 18:55 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1915 hrs on 28 November 2024

PRICES ARE NOW CONFIRMED for trading interval 28-Nov-2024 18:55.

In accordance with Market Notice 121192 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
121189RECLASSIFY CONTINGENCY28/11/2024 06:29:16 PM

Cancellation of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: NSW1

Lines: Armidale - Dumaresq 8C 330kV and Armidale - Sapphire WF 8E 330kV

Cancellation time: 28/11/2024 18:29

Constraint set(s) revoked:
N-ARDM_ARSR_1PH_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1


Refer AEMO Electricity Market Notice 121188

Auto-generated on behalf of Manager NEM Real Time Operations
     
121188RECLASSIFY CONTINGENCY28/11/2024 05:27:47 PM

Reclassification of a Non-Credible Contingency Event: Armidale - Dumaresq 8C 330kV line and Armidale - Sapphire WF 8E 330kV line in NSW1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: NSW1

Lines: Armidale - Dumaresq 8C 330kV and Armidale - Sapphire WF 8E 330kV

Duration: 28/11/2024 17:27 until further notice

Constraint set(s) invoked:
N-ARDM_ARSR_1PH_N-2 Constraint set contains the following interconnector(s) on the left hand side:
N-Q-MNSP1
NSW1-QLD1


Auto-generated on behalf of Manager NEM Real Time Operations
     
121187PRICES UNCHANGED28/11/2024 05:04:28 PM

[EventId:202411281640_confirmed] Prices for interval 28-Nov-2024 16:40 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1700 hrs on 28 November 2024

PRICES ARE NOW CONFIRMED for trading interval 28-Nov-2024 16:40.

In accordance with Market Notice 121176 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
121186PRICES UNCHANGED28/11/2024 05:02:58 PM

[EventId:202411281700_confirmed] Prices for interval 28-Nov-2024 17:00 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1700 hrs on 28 November 2024

PRICES ARE NOW CONFIRMED for trading interval 28-Nov-2024 17:00.

In accordance with Market Notice 121181 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
121185PRICES UNCHANGED28/11/2024 05:01:54 PM

[EventId:202411281655_confirmed] Prices for interval 28-Nov-2024 16:55 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1700 hrs on 28 November 2024

PRICES ARE NOW CONFIRMED for trading interval 28-Nov-2024 16:55.

In accordance with Market Notice 121179 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
121184PRICES UNCHANGED28/11/2024 05:00:19 PM

[EventId:202411281650_confirmed] Prices for interval 28-Nov-2024 16:50 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1700 hrs on 28 November 2024

PRICES ARE NOW CONFIRMED for trading interval 28-Nov-2024 16:50.

In accordance with Market Notice 121178 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
121183PRICES UNCHANGED28/11/2024 05:06:49 PM

[EventId:202411281645_confirmed] Prices for interval 28-Nov-2024 16:45 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 1700 hrs on 28 November 2024

PRICES ARE NOW CONFIRMED for trading interval 28-Nov-2024 16:45.

In accordance with Market Notice 121177 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.
     
X
Cookies help us improve your website experience.
By using our website, you agree to our use of cookies.
Confirm