Filter by category
Filter by Date
Minimum System Load 1 (MSL1) in the VIC Region on 31/12/2023
AEMO has detected that there is an elevated risk of insufficient demand to maintain a secure operating state in the Victorian region from 1100 hrs 31/12/2023 to 1400 hrs 31/12/2023.
Minimum scheduled demand is forecast to be 1300 MW at 1300 hrs and the secure threshold for the forecast operating conditions is 2,000 MW.
AEMO is seeking a market response.
An insufficient market response may require AEMO to take action or intervene to maintain power system security in Victoria. This may result in action such as the direction of scheduled generation, curtailment of non-scheduled generation, and/or a direction to increase operational demand.
Manager NEM Real Time Operations
NON-CONFORMANCE Region NSW1 Saturday, 30 December 2023
NON-CONFORMANCE NSW1 Region Saturday, 30 December 2023
AEMO has declared the following unit as non-conforming under clause 3.8.23 of the National Electricity Rules:
Unit: NEWENSF2
Duration: 30/12/2023 12:50 to 30/12/2023 13:05
Amount: 163 MW
Constraint: NC-N_NEWENSF2
Auto-generated on behalf of Manager NEM Real Time Operations
[EventId:202312291810_confirmed] Prices for interval 29-Dec-2023 18:10 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1835 hrs on 29 December 2023
PRICES ARE NOW CONFIRMED for trading interval 29-Dec-2023 18:10.
In accordance with Market Notice 112894 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202312291835_confirmed] Prices for interval 29-Dec-2023 18:35 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1835 hrs on 29 December 2023
PRICES ARE NOW CONFIRMED for trading interval 29-Dec-2023 18:35.
In accordance with Market Notice 112900 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202312291830_confirmed] Prices for interval 29-Dec-2023 18:30 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1835 hrs on 29 December 2023
PRICES ARE NOW CONFIRMED for trading interval 29-Dec-2023 18:30.
In accordance with Market Notice 112899 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202312291825_confirmed] Prices for interval 29-Dec-2023 18:25 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1835 hrs on 29 December 2023
PRICES ARE NOW CONFIRMED for trading interval 29-Dec-2023 18:25.
In accordance with Market Notice 112897 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202312291820_confirmed] Prices for interval 29-Dec-2023 18:20 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1835 hrs on 29 December 2023
PRICES ARE NOW CONFIRMED for trading interval 29-Dec-2023 18:20.
In accordance with Market Notice 112896 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
[EventId:202312291815_confirmed] Prices for interval 29-Dec-2023 18:15 are now confirmed
Issued by Australian Energy Market Operator Ltd at 1835 hrs on 29 December 2023
PRICES ARE NOW CONFIRMED for trading interval 29-Dec-2023 18:15.
In accordance with Market Notice 112895 AEMO has reviewed this trading interval and determined that:
- Manifestly Incorrect Inputs did not apply
Prices remain unchanged.
This is an AEMO autogenerated Market Notice.
Inter-regional transfer limit variation - constraint automation to manage Power System Security in QLD region - 29/12/2023
Inter-regional transfer limit variation - constraint automation to manage Power System Security in QLD region - 29/12/2023
In order to maintain the power system in a secure operating state in the QLD region, AEMO has invoked automated constraint set CA_SYDS_549FBEF5 from 1650 hrs until further notice.
This constraint set contains equations with the following interconnector on the LHS;
N-Q-MNSP1
Manager NEM Real Time Operations