Cancellation: Direction issued to: AGL SA Generation Pty Limited - TORRB4 TORRENS ISLAN
Cancellation: Direction issued to: AGL SA Generation Pty Limited - TORRB4 TORRENS ISLAN
Refer to Market Notice 119334
Direction is cancelled from: 1400 hrs 25/10/2024
Manager NEM Real Time Operations
Update Direction - Synergen Power Pty Limited - MINTARO MINTARO GAS
Update Direction - Synergen Power Pty Limited - MINTARO MINTARO GAS
Refer AEMO Electricity Participant Notice 119375
The MINTARO MINTARO GAS direction is now expected to stay in place until 1500 hrs 25/10/2024.
The direction update is issued at 1330 hrs 25/10/2024.
Manager NEM Real Time Operations
Foreseeable AEMO intervention under clause 4.8.5A (a) of the NER in SA region
Foreseeable AEMO intervention under clause 4.8.5A (a) of the NER in SA region
AEMO has identified a foreseeable circumstance that may require an AEMO intervention event in the SA region from 2100 hrs 25/10/2024.
The foreseeable circumstance requiring the need for intervention is Voltage.
Manager NEM Real Time Operations
Update Direction - Synergen Power Pty Limited - MINTARO MINTARO GAS
Update Direction - Synergen Power Pty Limited - MINTARO MINTARO GAS
Refer AEMO Electricity Participant Notice 119369
MINTARO MINTARO GAS at 1000 hrs 25/10/2024 to synchronise and follow dispatch targets.
This update is issued at 0945 hrs 25/10/2024 and is expected to stay in place until 1630 hrs 25/10/2024
Manager NEM Real Time Operations
Update Direction - SA region to Pelican Point Power Limited - PPCCGT PELICAN POINT
Update Direction - SA region to Pelican Point Power Limited - PPCCGT PELICAN POINT
Refer to Market Notices 119371 and 119198
Pelican Point Power Limited - PPCCGT PELICAN POINT is now expected to stay in place until 1000 hrs 25/10/2024.
The direction update is issued at 0943 hrs 25/10/2024.
Manager NEM Real Time Operations
NON-CONFORMANCE Region NSW1 Friday, 25 October 2024
NON-CONFORMANCE NSW1 Region Friday, 25 October 2024
AEMO has declared the following unit as non-conforming under clause 3.8.23 of the National Electricity Rules:
Unit: WTAHB1
Duration: 25/10/2024 08:30 to 25/10/2024 09:15
Amount: -9 MW
Constraint: NC-N_WTAHB1
Auto-generated on behalf of Manager NEM Real Time Operations
Update Direction - SA region to Pelican Point Power Limited - PPCCGT PELICAN POINT
Update Direction - SA region to Pelican Point Power Limited - PPCCGT PELICAN POINT
Refer to Market Notices 119365 and 119198
Pelican Point Power Limited - PPCCGT PELICAN POINT is now expected to stay in place until 0945 hrs 25/10/2024.
Manager NEM Real Time Operations
Cancellation: Direction issued to: AGL SA Generation Pty Limited - TORRB3 TORRENS ISLAN
Cancellation: Direction issued to: AGL SA Generation Pty Limited - TORRB3 TORRENS ISLAN
Refer to Market Notice 119366
Direction is cancelled from: 0900 hrs 25/10/2024
Manager NEM Real Time Operations
Direction - SA region 25/10/2024 to Synergen Power Pty Limited - MINTARO MINTARO GAS
Direction - SA region 25/10/2024 to Synergen Power Pty Limited - MINTARO MINTARO GAS
Refer to Market Notice 119198
In accordance with section 116 of the National Electricity Law, AEMO is issuing a direction to Synergen Power Pty Limited. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a1)(1).
Direction issued to: Synergen Power Pty Limited - MINTARO MINTARO GAS at 0905 hrs 25/10/2024
Type of resource: generating unit
Required actions: Synchronise and follow dispatch targets at 0945 hrs 25/10/2024
Services provided: Voltage Control
Circumstances necessitating the Direction: Voltage
Circumstances necessitating the Direction additional detail: The synchronous generating units currently expected to be synchronised in SA will be inadequate to maintain sufficient Voltage Control in SA. Intervention is required to maintain the power system in a secure operating state
Expected duration: 1630 hrs 25/10/2024 / further notice.
Synergen Power Pty Limited does not incur any civil monetary liability for a relevant action taken in accordance with this direction unless the action is taken in bad faith.
Manager NEM Real Time Operations