Market Notices

53562RECLASSIFY CONTINGENCY30/05/2016 01:20:56 AM

Reclassification of a Non-Credible Contingency Event: Ross - Chalumbin 857 and 858 275 kV Lines in Queensland due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event: Ross - Chalumbin 857 and 858 275 kV Lines in Queensland due to Lightning.

Lightning is occurring near the Ross - Chalumbin 857 and 858 275 kV Lines.

AEMO considers the simultaneous trip of those circuits to now be more likely.

Therefore AEMO has reclassified this as a credible contingency event from 0120 hrs 30/05/2016 until further notice.


Manager NEM Real Time Operations
53561RESERVE NOTICE29/05/2016 01:49:08 PM

Cancellation of the Forecast (LOR1) condition in the NSW region - PDPASA - 30 May 2016

AEMO ELECTRICITY MARKET NOTICE

Cancellation of the Forecast (LOR1) condition in the NSW region - PDPASA - 30 May 2016

The Forecast LOR1 condition in the NSW Region advised in AEMO Electricity Market Notice No. 53559 is cancelled at 1345 hrs 29 May 2016.


Manager NEM Real Time Operations
53559RESERVE NOTICE29/05/2016 12:53:39 PM

Forecast Lack Of Reserve Level 1 (LOR1) in the NSW Region - PDPASA - 30 May 2016

AEMO ELECTRICITY MARKET NOTICE

Forecast Lack Of Reserve Level 1 (LOR1) in the NSW Region - PDPASA - 30 May 2016

AEMO declares a Forecast LOR1 condition for the NSW Region.

From 1800 hrs to 1900 hrs 30 May 2016

The contingency capacity reserve required is 1400 MW

The minimum reserve available is 1264 MW


Manager NEM Real Time Operations
53558RECLASSIFY CONTINGENCY29/05/2016 01:24:45 PM

Cancellation Reclassification of a Non Credible Contingency Event: Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of Reclassification of a Non Credible Contingency Event: Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.
Refer AEMO Electricity Market Notice 53557
Constraint Set I-TE_ZERO to be revoked.
AEMO has cancelled the reclassification of the simultaneous trip of those circuits to be a credible contingency event from 1315 hrs 29 May 2016

Manager NEM Real Time Operations
53557RECLASSIFY CONTINGENCY29/05/2016 10:24:32 AM

Reclassification of a Non Credible Contingency Event: Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non Credible Contingency Event: Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.

A Bushfire exists in the vicinity of the Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.

AEMO has reclassified the simultaneous trip of those circuits to be a credible contingency event from 1015 hrs 29 May 2016 until further notice.

Constraint Set I-TE_ZERO invoked.


Manager NEM Real Time Operations
53433RECLASSIFY CONTINGENCY19/05/2016 11:10:02 PM

Cancellation of the Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of the Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.

Refer AEMO Electricity Market Notice 53432

There is no longer any lightning activity in the vicinity of the Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line.

AEMO has cancelled the reclassification of the simultaneous trip of those circuits as a credible contingency event at 2310 hrs.


Manager NEM Real Time Operations
53432RECLASSIFY CONTINGENCY19/05/2016 10:10:05 PM

Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.

Lightning is occurring near the Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line.

AEMO considers the simultaneous trip of those circuits to now be more likely.

Therefore AEMO has reclassified this as a credible contingency event from 2210 hrs 19/05/16 until further notice.

Manager NEM Real Time Operations
53428RECLASSIFY CONTINGENCY19/05/2016 01:09:10 PM

Cancellation of the Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of the Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.

Refer AEMO Electricity Market Notice 53427

There is no longer any lightning activity in the vicinity of the Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line.

AEMO has cancelled the reclassification of the simultaneous trip of those circuits as a credible contingency event at 1255hrs.


Manager NEM Real Time Operations
53427RECLASSIFY CONTINGENCY19/05/2016 12:12:25 PM

Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event: Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line in Tasmania due to Lightning.
Lightning is occurring near the Farrell - John Butters 220 kV Line and the Farrell - Rosebery Tee Queenstown - Newton 110 kV Line.
AEMO considers the simultaneous trip of those circuits to now be more likely.
Therefore AEMO has reclassified this as a credible contingency event from 1210 hrs 19 MAY 2016 until further notice.

Manager NEM Real Time Operations
X
Cookies help us improve your website experience.
By using our website, you agree to our use of cookies.
Confirm