Market Notices

89001PRICES SUBJECT TO REVIEW28/07/2021 09:15:20 AM

[EventId:202107280920_review] Prices for interval 28-Jul-2021 09:20 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 0915 hrs on 28 July 2021

PRICES ARE SUBJECT TO REVIEW for dispatch interval 28-Jul-2021 09:20.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
89000PRICES SUBJECT TO REVIEW28/07/2021 09:10:19 AM

[EventId:202107280915_review] Prices for interval 28-Jul-2021 09:15 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 0910 hrs on 28 July 2021

PRICES ARE SUBJECT TO REVIEW for dispatch interval 28-Jul-2021 09:15.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
88999PRICES SUBJECT TO REVIEW28/07/2021 09:05:16 AM

[EventId:202107280910_review] Prices for interval 28-Jul-2021 09:10 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 0905 hrs on 28 July 2021

PRICES ARE SUBJECT TO REVIEW for dispatch interval 28-Jul-2021 09:10.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
88998PRICES SUBJECT TO REVIEW28/07/2021 09:00:16 AM

[EventId:202107280905_review] Prices for interval 28-Jul-2021 09:05 are subject to review

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 0900 hrs on 28 July 2021

PRICES ARE SUBJECT TO REVIEW for dispatch interval 28-Jul-2021 09:05.

AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs


This is an AEMO autogenerated Market Notice.
88997RECLASSIFY CONTINGENCY28/07/2021 07:35:10 AM

Reclassification of a Non-Credible Contingency Event: Farrell - Reece No.1 220 kV line and Farrell - Reece No.2 220 kV line in TAS1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: TAS1

Lines: Farrell - Reece No.1 220 kV and Farrell - Reece No.2 220 kV

Duration: 28/07/2021 07:35 until further notice

Constraint set(s) invoked:
F-T-FARE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
T-V-MNSP1


Auto-generated on behalf of Manager NEM Real Time Operations
88996MARKET SYSTEMS27/07/2021 09:11:21 PM

INC0073410 - Issue with the RM27 Reports

INC0073410 - Issue with the RM27 Reports

AEMO ELECTRICITY MARKET NOTICE
INC0073410 - Issue with the RM27 reports - ALERT

AEMO is experiencing an issue with the RM27 reports(Level2SettlementReconciliation)

Participants are advised that AEMO have identified an issue with the RM27 reports (Level2SettlementReconciliation). Please note: There will be no RM27/RM16 issued for week 27 final tonight.

AEMO is investigating the issue and will provide an update by 28/07/2021 09:30 AEST.

For further enquiries please contact the AEMO Support Hub
Phone: 1300 236 600
Email: supporthub@aemo.com.au

AEMO IT Duty Manager
88995GENERAL NOTICE27/07/2021 07:56:17 PM

Cancellation : Non-credible contingency event more likely to occur due to existence of abnormal condition/s - SA region.

AEMO ELECTRICITY MARKET NOTICE.

Abnormal conditions advised in AEMO Electricity Market Notice 88971 have ceased to impact the likelihood of a non-credible event occurring as at 2000 hrs 27/07/2021

Manager NEM Real Time Operations
88986INTER-REGIONAL TRANSFER27/07/2021 12:29:47 PM

Inter-Regional Transfer limit variation - Murraylink

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Murraylink

A short notice outage has been requested on the Murraylink interconnector.

The following constraint set was invoked at 1220 hrs 27/07/2021

I-ML_ZERO

The constraint set contains the following interconnector on the left hand side.

V-S-MNSP1

Refer to AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
88985PRICES UNCHANGED27/07/2021 10:02:13 AM

[EventId:202107270930_confirmed] Prices for interval 27-Jul-2021 09:30 are now confirmed

AEMO ELECTRICITY MARKET NOTICE

Issued by Australian Energy Market Operator Ltd at 0950 hrs on 27 July 2021

PRICES ARE NOW CONFIRMED for dispatch interval 27-Jul-2021 09:30.

In accordance with Market Notice 88974 AEMO has reviewed this dispatch interval and determined that:
- Manifestly Incorrect Inputs did not apply

Prices remain unchanged.


This is an AEMO autogenerated Market Notice.