Reclassification of a Non Credible Contingency Event: Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.
Reclassification of a Non Credible Contingency Event: Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.
A Bushfire exists in the vicinity of the Mudgeeraba Terranora 757 and 758 110 kV Lines in Queensland due to Bushfire.
AEMO has reclassified the simultaneous trip of those circuits to be a credible contingency event from 1015 hrs 29 May 2016 until further notice.
Constraint Set I-TE_ZERO invoked.
Manager NEM Real Time Operations
Cancellation - Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
Cancellation - Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
The AEMO Dynamic Stability Analysis application is indicating violations for a fault on a Hazelwood - South Morang 500 kV transmission line in the Victoria region. The following constraint set has been invoked to apply offset reduction to the Victoria transient stability export limit.
Constraint V-DSA_STAB-50 invoked from 0155 hrs to 0220 hrs.
Constraint V-DSA_STAB-100 invoked from 0220 hrs to 0240 hrs.
Constraint V-DSA_STAB-150 invoked from 0240 hrs to 0500 hrs.
Constraint V-DSA_STAB-100 invoked from 0500 hrs to 0600 hrs
Constraints have the following interconnectors on the LHS
NSW1-QLD1
T-V-MNSP1
V-SA
V-S-MNSP1
VIC1-NSW1
Manager NEM Real Time Operations
Update - Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
Update - Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
The AEMO Dynamic Stability Analysis application is indicating violations for a fault on a Hazelwood - South Morang 500 kV transmission line in the Victoria region. The following constraint set has been invoked to apply offset reduction to the Victoria transient stability export limit.
Constraint V-DSA_STAB-50 invoked from 0155 hrs to 0220 hrs.
Constraint V-DSA_STAB-100 invoked from 0220 hrs to 0240 hrs.
Constraint V-DSA_STAB-150 invoked from 0240 hrs to 0500 hrs.
Constraint V-DSA_STAB-100 invoked from 0500 hrs until further notice.
Constraints have the following interconnectors on the LHS
NSW1-QLD1
T-V-MNSP1
V-SA
V-S-MNSP1
VIC1-NSW1
Manager NEM Real Time Operations
Update - Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
Update - Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
The AEMO Dynamic Stability Analysis application is indicating violations for a fault on a Hazelwood - South Morang 500 kV transmission line in the Victoria region. The following constraint set has been invoked to apply offset reduction to the Victoria transient stability export limit.
Constraint V-DSA_STAB-50 invoked from 0155 hrs to 0220 hrs.
Constraint V-DSA_STAB-100 invoked from 0220 hrs to 0240 hrs.
Constraint V-DSA_STAB-150 invoked from 0240 hrs until further notice.
Constraints have the following interconnectors on the LHS
NSW1-QLD1
T-V-MNSP1
V-SA
V-S-MNSP1
VIC1-NSW1
Manager NEM Real Time Operations
Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
The AEMO Dynamic Stability Analysis application is indicating violations for a fault on a Hazelwood - South Morang 500 kV transmission line in the Victoria region. The following constraint set has been invoked to apply offset reduction to the Victoria transient stability export limit.
Constraint V-DSA_STAB-50 invoked from 0155 hrs to 0220 hrs.
Constraint V-DSA_STAB-100 invoked from 0220 hrs until further notice.
Constraints have the following interconnectors on the LHS
NSW1-QLD1
T-V-MNSP1
V-SA
V-S-MNSP1
VIC1-NSW1
Manager NEM Real Time Operations
Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
Inter-regional transfer limit variation for Transient Stability Limit Victoria Region 29 May 2016
The AEMO Dynamic Stability Analysis application is indicating violations for a fault on a Hazelwood - South Morang 500 kV transmission line in the Victoria region. The following constraint set has been invoked to apply offset reduction to the Victoria transient stability export limit.
Constraint V-DSA_STAB-50 invoked from 0155 hrs until further notice.
Constraints have the following interconnectors on the LHS
NSW1-QLD1
T-V-MNSP1
V-SA
V-S-MNSP1
VIC1-NSW1
Manager NEM Real Time Operations
NON-CONFORMANCE Region QLD1 Saturday, 28 May 2016
NON-CONFORMANCE QLD1 Region Saturday, 28 May 2016
AEMO declared a schedule generating unit non-conforming
Unit: CALL_B_2
Duration: 28/05/2016 10:50 to 28/05/2016 10:55
Amount: 13 MW
Constraint: NC-Q_CALL_B_2
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region SA1 Saturday, 28 May 2016
NON-CONFORMANCE SA1 Region Saturday, 28 May 2016
AEMO declared a schedule generating unit non-conforming
Unit: TORRA4
Duration: 28/05/2016 09:30 to 28/05/2016 09:40
Amount: -18 MW
Constraint: NC-S_TORRA4
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region NSW1 Friday, 27 May 2016
NON-CONFORMANCE NSW1 Region Friday, 27 May 2016
AEMO declared a schedule generating unit non-conforming
Unit: MP2
Duration: 27/05/2016 16:20 to 27/05/2016 16:25
Amount: 84 MW
Constraint: NC-N_MP2
Auto-generated on behalf of Manager NEM Real Time Operations