Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) condition in the South Australia region - STPASA - 24 August 2016
Cancellation of the Forecast Lack Of Reserve Level 1 (LOR1) condition in the South Australia region - STPASA - 24 August 2016.
The Forecast LOR1 condition in the SA Region advised in AEMO Electricity Market Notice No.54762 is cancelled at 1400 hrs on 22 August 2016.
LOR conditions are no longer forecast in the STPASA period.
Harmohan Singh
Operations Planning
Forecast Lack Of Reserve Level 1 (LOR1) in the South Australia region - STPASA - 24/08/2016
AEMO declares a Forecast LOR1 condition for the South Australia region for the following period:
From 24/08/2016 1830 hrs to 2000 hrs
The contingency capacity reserve required is 400 MW.
The minimum reserve available is 361 MW.
Harmohan Singh
Operations Planning
Planned outage of Moorabool to Mortlake PS 500kV line in Victoria region from 15/09/2016 0700 hrs to 15/09/2016 1700 hrs
This market notice is FOR INFORMATION ONLY.
The Moorabool to Mortlake PS 500kV line in Victoria Region is planned out of service from 0700 hrs on 15 September 2016 to 1700 hrs on 15 September 2016.
During this outage, a credible contingency can separate South Australia region from the rest of the NEM.
Under these circumstances, 35 MW of Raise and Lower regulation FCAS will be sourced from South Australia for the duration of this outage. In addition, consistent with AEMO existing procedures, adequate contingency FCAS lower requirements will also be sourced from South Australia at times when power transfer is from South Australia to Victoria.
The following constraint sets have been invoked for this outage:
F-V-MLMO (includes F-S_LREG_0035 and F-S_RREG_0035)
S-BOTH_BLKRG_C_OS
V-MLMO
Refer AEMO Network Outage Schedule (NOS) for further details.
AEMO will continue monitoring this proposed outage and will update the Market accordingly.
Edmund Hon
AEMO Operations
Planned outage of Moorabool to Mortlake PS 500kV line in Victoria region from 14/09/2016 0700 hrs to 14/09/2016 1700 hrs
This market notice is FOR INFORMATION ONLY.
The Moorabool to Mortlake PS 500kV line in Victoria Region is planned out of service from 0700 hrs on 14 September 2016 to 1700 hrs on 14 September 2016.
During this outage, a credible contingency can separate South Australia region from the rest of the NEM.
Under these circumstances, 35 MW of Raise and Lower regulation FCAS will be sourced from South Australia for the duration of this outage. In addition, consistent with AEMO existing procedures, adequate contingency FCAS lower requirements will also be sourced from South Australia at times when power transfer is from South Australia to Victoria.
The following constraint sets have been invoked for this outage:
F-V-MLMO (includes F-S_LREG_0035 and F-S_RREG_0035)
S-BOTH_BLKRG_C_OS
V-MLMO
Refer AEMO Network Outage Schedule (NOS) for further details.
AEMO will continue monitoring this proposed outage and will update the Market accordingly.
Edmund Hon
AEMO Operations
Planned outage of Moorabool to Mortlake PS 500kV line in Victoria region from 13/09/2016 0700 hrs to 13/09/2016 1700 hrs
This market notice is FOR INFORMATION ONLY.
The Moorabool to Mortlake PS 500kV line in Victoria Region is planned out of service from 0700 hrs on 13 September 2016 to 1700 hrs on 13 September 2016.
During this outage, a credible contingency can separate South Australia region from the rest of the NEM.
Under these circumstances, 35 MW of Raise and Lower regulation FCAS will be sourced from South Australia for the duration of this outage. In addition, consistent with AEMO existing procedures, adequate contingency FCAS lower requirements will also be sourced from South Australia at times when power transfer is from South Australia to Victoria.
The following constraint sets have been invoked for this outage:
F-V-MLMO (includes F-S_LREG_0035 and F-S_RREG_0035)
S-BOTH_BLKRG_C_OS
V-MLMO
Refer AEMO Network Outage Schedule (NOS) for further details.
AEMO will continue monitoring this proposed outage and will update the Market accordingly.
Edmund Hon
AEMO Operations
Dispatch and reconciliation reporting issue with local FCAS regulation recovery
Reports: DISPATCH_FCAS_REQ, PREDISPATCH_FCAS_REQ, and SET_FCAS_REGULATION_TRK
AEMO advises that DISPATCH_FCAS_REQ and PREDISPATCH_FCAS_REQ estimation reports and SET_FCAS_REGULATION_TRK reconciliation will not correctly account for Market Participants with generation in multiple NEM regions under different Participant IDs for local FCAS regulation requirements. This does not impact the calculation of settlement amounts, and only applies to requirements for local regulation FCAS.
AEMO estimates settlement amounts for each participant on a daily basis as part of routine prudential monitoring, and this information is distributed to each participant shortly after the end of the settlement day (ending midnight). These amounts are not impacted by the dispatch and reconciliation reporting issue.
AEMO is currently working on a fix to all three reports, and the fix will be in place by Friday 26 August 2016.
If you have questions relating to this matter please contact Chin Chan, Group Manager Market Management via 03 9609 8345.
Outage cancelled - Planned outage of Moorabool to Mortlake PS 500kV line in Victoria region from 28/08/2016 0630 hrs to 28/08/2016 1800 hrs
** The outage have been cancelled by Ausnet **
This market notice is FOR INFORMATION ONLY.
The Moorabool to Mortlake PS 500kV line in Victoria Region is planned out of service from 0630 hrs on 28 August 2016 to 1800 hrs on 28 August 2016.
During this outage, a credible contingency can separate South Australia region from the rest of the NEM.
Under these circumstances, 35 MW of Raise and Lower regulation FCAS will be sourced from South Australia for the duration of this outage. In addition, consistent with AEMO existing procedures, adequate contingency FCAS lower requirements will also be sourced from South Australia at times when power transfer is from South Australia to Victoria.
The following constraint sets have been invoked for this outage:
F-V-MLMO (includes F-S_LREG_0035 and F-S_RREG_0035)
S-BOTH_BLKRG_C_OS
V-MLMO
Refer AEMO Network Outage Schedule (NOS) for further details.
AEMO will continue monitoring this proposed outage and will update the Market accordingly.
Operations Planning
Outage cancelled - Planned outage of Moorabool to Tarrone 500kV line in Victoria region from 27/08/2016 0630 hrs to 27/08/2016 1800 hrs
** The outage have been cancelled by Ausnet **
This market notice is FOR INFORMATION ONLY.
The Moorabool to Tarrone 500kV line in Victoria Region is planned out of service from 0630 hrs on 27 August 2016 to 1800 hrs on 27 August 2016.
During this outage, a credible contingency can separate South Australia region from the rest of the NEM.
Under these circumstances, 35 MW of Raise and Lower regulation FCAS will be sourced from South Australia for the duration of this outage. In addition, consistent with AEMO existing procedures, adequate contingency FCAS lower requirements will also be sourced from South Australia at times when power transfer is from South Australia to Victoria.
The following constraint sets have been invoked for this outage:
F-V-MLTR (includes F-S_LREG_0035 and F-S_RREG_0035)
S-BOTH_BLKRG_C_OS
V-MLTR
V-MACARTHUR_ZERO
Refer AEMO Network Outage Schedule (NOS) for further details.
AEMO will continue monitoring this proposed outage and will update the Market accordingly.
Edmund Hon
AEMO Operations
Outage cancelled - Planned outage of Moorabool to Mortlake PS 500kV line in Victoria region from 21/08/2016 0630 hrs to 21/08/2016 1800 hrs
** The outage has been cancelled by Ausnet **
This market notice is FOR INFORMATION ONLY.
The Moorabool to Mortlake PS 500kV line in Victoria Region is planned out of service from 0630 hrs on 21 August 2016 to 1800 hrs on 21 August 2016.
During this outage, a credible contingency can separate South Australia region from the rest of the NEM.
Under these circumstances, 35 MW of Raise and Lower regulation FCAS will be sourced from South Australia for the duration of this outage. In addition, consistent with AEMO existing procedures, adequate contingency FCAS lower requirements will also be sourced from South Australia at times when power transfer is from South Australia to Victoria.
The following constraint sets have been invoked for this outage:
F-V-MLMO (includes F-S_LREG_0035 and F-S_RREG_0035)
S-BOTH_BLKRG_C_OS
V-MLMO
Refer AEMO Network Outage Schedule (NOS) for further details.
AEMO will continue monitoring this proposed outage and will update the Market accordingly.
Operations Planning