Filter by category
Filter by Date
NON-CONFORMANCE Region QLD1 Tuesday, 4 July 2017
NON-CONFORMANCE QLD1 Region Tuesday, 4 July 2017
AEMO declared a schedule generating unit non-conforming
Unit: BRAEMAR3
Duration: 04/07/2017 17:45 to 04/07/2017 17:55
Amount: -40 MW
Constraint: NC-Q_BRAEMAR3
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region QLD1 Monday, 3 July 2017
NON-CONFORMANCE QLD1 Region Monday, 3 July 2017
AEMO declared a schedule generating unit non-conforming
Unit: STAN-2
Duration: 03/07/2017 10:45 to 03/07/2017 10:55
Amount: -8 MW
Constraint: NC-Q_STAN-2
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region SA1 Monday, 3 July 2017
NON-CONFORMANCE SA1 Region Monday, 3 July 2017
AEMO declared a schedule generating unit non-conforming
Unit: PPCCGT
Duration: 03/07/2017 06:35 to 03/07/2017 06:40
Amount: -40 MW
Constraint: NC-S_PPCCGT
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region QLD1 Sunday, 2 July 2017
NON-CONFORMANCE QLD1 Region Sunday, 2 July 2017
AEMO declared a schedule generating unit non-conforming
Unit: TARONG#1
Duration: 02/07/2017 13:00 to 02/07/2017 13:05
Amount: 45 MW
Constraint: NC-Q_TARONG#1
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region SA1 Saturday, 1 July 2017
NON-CONFORMANCE SA1 Region Saturday, 1 July 2017
AEMO declared a schedule generating unit non-conforming
Unit: MINTARO
Duration: 01/07/2017 17:25 to 01/07/2017 17:30
Amount: 46 MW
Constraint: NC-S_MINTARO
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region NSW1 Saturday, 24 June 2017
NON-CONFORMANCE NSW1 Region Saturday, 24 June 2017
AEMO declared a schedule generating unit non-conforming
Unit: ER01
Duration: 24/06/2017 16:25 to 24/06/2017 16:30
Amount: -75 MW
Constraint: NC-N_ER01
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region VIC1 Friday, 23 June 2017
NON-CONFORMANCE VIC1 Region Friday, 23 June 2017
AEMO declared a schedule generating unit non-conforming
Unit: JLA01
Duration: 23/06/2017 11:35 to 23/06/2017 11:45
Amount: -20 MW
Constraint: NC-V_JLA01
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region QLD1 Thursday, 22 June 2017
NON-CONFORMANCE QLD1 Region Thursday, 22 June 2017
AEMO declared a schedule generating unit non-conforming
Unit: STAN-2
Duration: 22/06/2017 12:45 to 22/06/2017 12:55
Amount: -9 MW
Constraint: NC-Q_STAN-2
Auto-generated on behalf of Manager NEM Real Time Operations
NON-CONFORMANCE Region NSW1 Thursday, 22 June 2017
NON-CONFORMANCE NSW1 Region Thursday, 22 June 2017
AEMO declared a schedule generating unit non-conforming
Unit: SITHE01
Duration: 22/06/2017 05:30 to 22/06/2017 05:40
Amount: 41 MW
Constraint: NC-N_SITHE01
Auto-generated on behalf of Manager NEM Real Time Operations